| MULTIVOLTAGE STATIC FEEDER FOR RAILWAY CARRIAGE TESTING
DATA SHEET |

|
1.
Features
The purpose of the apparatus is to provide, from the mains voltage 400V,
the four voltages emploied on the european carriage: 3000Vdc, 1500Vdc, 1500Vac and 1000Vac 16,6Hz.
These voltages are stabilized and manually settable. |
|
2. Technical data
|
| •
Input voltage: |
400V 3F |
| •
Input voltage range: |
± 15% |
| •
Input frequency: |
± 5% |
| •
Rated powe: |
100kW |
| |
|
| •
OUTPUT VOLTAGE 1: |
3000V corrente continua |
| •
Range settable: |
1620Vcc ÷ 4255Vcc |
| •
Static stability |
± 1,5% |
| •
Dynamic stability (with load variation ± 60%): |
± 8% |
| •
Ripple (RMS): |
4% |
| •
Overload for 10 minutes: |
125% |
| •
Short circuit current: |
150% |
| |
|
| •
OUTPUT VOLTAGE 2: |
1500V corrente continua |
| •
Range settable: |
810Vcc ÷ 2155Vcc |
| •
Static stability: |
± 1,5% |
| •
Dynamic stability (with load variation ± 60%): |
± 8% |
| •
Ripple (RMS): |
4% |
| •
Overload for 10 minutes: |
125% |
| •
Short circuit current: |
150% |
| |
|
| •
OUTPUT VOLTAGE 3: |
1500V monofase |
| •
Range settable: |
1140V ÷ 1760V |
| •
Nominal frequency: |
50Hz ± 0,5Hz |
| •
Waveform: |
sinusoidale |
| •
THD: |
5% |
| •
Static stability: |
± 1,5% |
| •
Dynamic stability (with load variation ± 60%): |
± 8% |
| •
Overload for 10 minutes: |
125% |
| •
Short circuit current: |
150% |
| |
|
| •
OUTPUT VOLTAGE 4: |
1000V monofase |
| •
Range settable: |
600V ÷ 1100V |
| •
Nominal frequency: |
16,6Hz ± 0,5Hz |
| •
Waveform: |
sinusoidale |
| •
THD: |
5% |
| •
Stabilità statica: |
± 1,5% |
| •
Dynamic stability (with load variation ± 60%): |
± 8% |
| •
Overload for 10 minutes: |
125% |
| •
Short circuit current: |
150% |
|
|
| |
3. Miscellaneous
|
| •
Range working temperature: |
-5°C ÷ +45°C |
| •
Max temperature daily average: |
35°C |
| •
Altitude without downgrading: |
1000m |
| •
Relative humidity at 45°C (without condensing): |
90% |
| •
Dimensions: |
2000x950x1850mm |
| •
Weight: |
1500kg |
| •
Losses: |
10kW |
|
| |
4. 4. Meters
|
| •
DC voltmeter |
| •
DC amperometer |
| •
AC voltmeter (50Hz, 16,6Hz) |
| •
AC amperometer (50Hz, 16,6Hz) |
| •
Frequency meter |
|
| |
5. Signalling
|
| •
Working converter |
| •
Fault converter |
| •
Overtemperature |
| •
3000Vdc switch on |
| •
1500Vdc switch on |
| •
1500Vac 50Hz switch on |
| •
1000Vac 16,6Hz switch on |
|
| |
6. Telealarms (on request)
|
| •
Working converter |
| •
Fault converter |
| •
Overtemperature |
| •
3000Vdc switch on |
| •
1500Vdc switch on |
| •
1500Vac 50Hz switch on |
| •
1000Vac 16,6Hz switch on |
|
| |
7. Local controls
|
| •
Key selector 3000Vdc selection |
| •
Key selector 1500Vdc selection |
| •
Key selector 1500Vac 50Hz selection |
| •
Key selector 1000Vac 16,6Hz selection |
| •
Calibration 3000Vdc |
| •
Calibration 1500Vdc |
| •
Calibration 1500Vac 50Hz |
| •
Calibration 1000Vac 16,6Hz |
|
| |
8. Switches
|
| •
Input automatic breaker with locked key. |
| •
Output switch at two positions: output connected to
converter/ output connected to the ground.
Double locked keys with keys switched and locked for on position. |
|
ELIT Srl reserves his right to do modifications to his products
without notice |
| download pdf |
 |
ask for a
quotation |
 |
|